The Atomic Absorption Spectrophotometer (SP-IAA320) is a professional laboratory instrument from the Atomic Absorption Spectrophotometer range, available from EcoScientific.
Technical Specifications
| Parameter | Value |
|---|---|
| WL range | 190-900nm |
| WL accuracy | ≤±0.5nm |
| WL repeatability | ≤0.3nm (single direction) |
| Spectrum bandwidth | 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm |
| Resolution | <40% |
| Base line stability | ±0.004Abs/30min |
| Characteristic concentration of copper | ≤0.04µg/ml/1% |
| Detection limit of copper | ≤0.008µg/ml |
| Background calibration ability | Greater than 30 times |
| RS232 | Including |
| Printer | Optional |
| Power supply | 220V 3A, 50Hz; 138kg(Main instrument); 56kg(Accessories) |
| Package Dimension (W*D*H) | 1260*800*770mm (Main instrument); 560*460*1400mm (Accessories) |
| Atomic Absorption Spectrophotometer | Advantages; Complete Automatic Controlling System |
| SP-IAA4530 | With the help of the software, the following can be easily achieved; Selection of the element lamp; Up-down-front-rear adjustment of the lifter; Adjustment of the optical energy; Selection of the slit |
| The atomic absorption spectropho- | The bringing in of PID technology can effectively overcome the influence |
| tometer is completely controlled and | on the temperature rising process caused by the voltage fluctuation and |
| operated by PC, with unique optical | the resistance change to make more accurate controlling process. The |
| and mechanical design, safe and | combination of the 3ms/time fast sampling technique can make more |
| convenient flame system, advanced | accurate and reliable testing data |
| graphite furnace temperature | The fast heating capacity can improve the flexibility of the elements |
| control technology and various | further |
| convenient functions provided by the | Use the ordinary power source of 220V without need of dynamic power of |
| workstation. | 380V; The maximum procedure heating capacity setting of 20 levels can make a; more convenient and easier test of different samples; Three grades adjustable gas flow can accustom to more application; Can timely alarm when the gas and water is stopped and insufficient gas |
| technology | can alarm whenever the electricity is cut off, abnormal flame occurs, a; lack of pressure happens or the burner does not match well. And it will; automatically turn off the gas, prohibit tempering. Thus it keeps the |
Part of the Spectrophotometer range available from EcoScientific. Request a quote for pricing and availability in South Africa.